Beijing Oriental yangseng Mechanical & Electronic Co., Ltd.

Manufacturer from China
Active Member
13 Years
Home / Products / Fractional CO2 Laser /

RF Drive Fractional CO2 Laser

Contact Now
Beijing Oriental yangseng Mechanical & Electronic Co., Ltd.
City:Beijing
Province/State:Beijing
Contact Person:yangchangfeng
Contact Now

RF Drive Fractional CO2 Laser

Ask Latest Price
Video Channel
Type :Laser
Laser Type :CO2 Laser
Q-Switch :No
Style :Stationary
Certification :CE ISO
machine type :fractional CO2 laser
Wavelength :10.6 um
Max power :50 Watts
Scan mode :Ellipse Scan, Rectangle Scan, Triangle Scan
Laser type :RF driver CO2 laser
Laser indicator :650nm ruby laser
Control system :digital micro computer system
Conduct system :seven-joints laser articulated arms
Size :350(W)x670(L)x850(H)mm
Voltage :220V/110V, 50/60HZ 10A
MOQ :1 Set/Sets fractional co2 laser Sample
Packaging Details :Aluminous Case
Delivery Time :3-5 working days
Payment Terms :L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability :10 Set/Sets per Week OEM
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

RF drive fractional co2 laser
1.Scars Removal
2.Shrink pores, fine wrinkles, skin whitening

OW-G1 RF drive Fractional CO2 Laser

Picture

Name

Fractional Co2 Laser Beauty Machine

Feature

Co2 laser Scar Removal

Function

Main Function

Scars Removal

Secondary Function

1,All kinds of excavated type of scars(Like traumatic scars, surgical scars and smallpox scar)

2,All kinds of scars, blotches and splashes

3,Shrink large pores, fine wrinkles, skin whitening and stretch marks removal
4,Photoaging and skin excrescence improvement.

Theory

Laser Beam forms fine and precise MTZs (Micro-Thermal Treatment Zones) against the skin area with application of the principal that helps the collagen regenerate by penetrating deep into dermis layer and leading the normal skin to accelerate natural skin-regeneration.

advantages

Better removing smallpox scars, skin excrescence with smaller side-effects.

Specifications

Power source

2000W

Handle

Fractional co2 laser

Wavelength

10600nm

Spot mode

Single mode

Spot diameter

0.25mm

Spot size

0.05mm2

Maximum output power

50Watts

Screen

digital micro computer system

Scan graphic

Ellipse, rectangle, triangle, square, hexagon, linear, rotundity

Scan mode

Sequential scanning, non-sequential scanning, parallel processing scanning

Output model

Ultra pulse, dot-matrix

Working manner

Intermittent loading& continuous operation

Operating language

English/French/Chinese(Changeable)

Laser type

Co2 laser

Cooling system

Wind cooling

Input power

AC 220V±10%,50Hz

Size

Machine size

130*50*45cm

Package size

135*55*50cm

Net weight

56kg

Gross weight

68kg

packing

Aluminous case

Body material

ABS

Machine color

White

warranty

3-year

Accessories

Taboos

  1. 1 Pregnant or women nursing.
  2. Epileptic
  3. Patients with malignant tumor.
  4. Patients with acute inflammation and wound infection
  5. Patients without recovery from surgical wound.
  6. Patients with heart disease or with a cardiac pacemaker.
  7. Patients with severe diabetes
  8. Heart, brain, nerve head, backbone, eyeball, bleeding, injection.
  9. Metal uterus global( other area can be treated)
  10. Person who once had abdominal surgery during menses, period of birth control and urinary incontinence
  11. Person with much inner fever.
  12. Atopic person.
  13. Patients with high fever
  14. Severe telangiectasia, maybe take steroid
  15. hormone and have endocrine Disorders for a long time( other area can be treated)
  16. Hemophiliac and person with serious bleeding.

After treatment proposal

1,Keep the treating area clean and dry for 3-7 days, do cleaning with wet towel.

2,Use OTC antibiotic drugs in the treating area for anti-infection, or not use anything else.

3,Waiting the treating area scab itself, do not try to force it scab for you may hurt the surface then cause a longer healing period.

4,If the naked parts scabbed itself, do avoid sun burning or paints sun cream to prevent pigmentation. If pigmentation occurs, please use anti blotch cream or wait for 3 months or more time for it to fade.

5,After scabbing, please check in the clinic for remaining. If so, please do a second treatment as soon as possible.

After sale service and Quality Warranty

  1. We supply three year warranty for themainframe. For other parts or parts over warranty, we supply repairing service and maintenancetoo, but we would ask for some charges for the service and replacement parts.
  2. We will not supply warranty if any following condition.

a. there is a malfunction caused by disassembly the machine without our permission.

b. there is a malfunction caused by not carefully use (fall down or shock the machine).

c. There is a malfunction caused by no maintenance.

d. There is a malfunction caused by incorrect operation.

Cautions

  1. Please put water in and let it cycle for 2-3 times before using, in order to make the machine working smoothly.
  2. If there’s malfunction caused by non human reason which requires delivering back for maintenance, the charge shall be the customer’s.

Before& After






Inquiry Cart 0